Empower induction heating power, tuned circuit etc. Do you want a short lead time of medium frequency capacitor recommendation? Trustworthy technical team to customize the most efficient capacitor banks for your induction heating machines.Empower induction heating power, tuned circuit etc. Do you want a short lead time of medium frequency capacitor recommendation? Trustworthy technical team to customize the most efficient capacitor banks for your induction heating machines.
Empower induction heating power, tuned circuit etc. Do you want a short lead time of medium frequency capacitor recommendation? Trustworthy technical team to customize the most efficient capacitor banks for your induction heating machines.Empower induction heating power, tuned circuit etc. Do you want a short lead time of medium frequency capacitor recommendation? Trustworthy technical team to customize the most efficient capacitor banks for your induction heating machines.
Technical parameter
No |
Description |
Unit |
Data |
1 |
Rated voltage(AC) |
Un |
0.7kV |
2 |
Rated frequency |
Fn |
100 Hz |
3 |
Capacity |
Kvar |
1090kvar |
4 |
Capacitance |
Cn |
3540μF (+10%~-5%) |
5 |
Current |
In(A) |
1557A |
6 |
water flow rate |
L/min |
≥8L/min |
7 |
Max.Water temperature |
℃ |
≦40°C |
9 |
Loss |
|
<0.5 W/kvar |
Mechanical Properties and Structure
No |
Description |
Data |
1 |
Case Dimension |
348*241*1010mm (±3mm) |
2 |
Case Materials |
Patterned Aluminium alloy (Non-Magnetic) |
3 |
Terminal conduit |
Compound materials |
4 |
Max tightening Torque |
18N m |
5 |
Dielectric |
All-film |
6 |
Impregnation |
Biodegradable Insulation oil (M/DBT), non-PCB |
7 |
Shell type |
Insulated (Dead case) |
8 |
Cooling method |
Water-cooling |
9 |
Built-in water tubes Nos |
2 |
10 |
Protection |
Pressure Switch; >0.08MPA off; <0.05MPA on |
Outline Drawing