0102030405
High Voltage Power Capacitors from China Suppliers - Factory Direct Solutions for Power Quality Up to 1000Kvar
HV Power Capacitor Features
⚡
System Voltage: above 6KV
⚡
Capacity range: 50Kvar~1000Kvar
⚡
Rated Capacitor voltage: Max 24KV
⚡
Internal fuse, external fuse, fuseless available
⚡
3 phase, Y connection internal, resistors for each phase
⚡
Structure as below picture
Specification Table
Table 1. The internal fuse HV power capacitor
| Model | Rated voltage KV | Rated output Kvar | Case Dimension (mm) | Total height (mm) | Terminals D (mm) | Remark | ||
|---|---|---|---|---|---|---|---|---|
| L | W | H | ||||||
| FBC-MSO | 6.6/√3 | 134 | * | 145 | 390 | 615 | 135 | Internal fuse |
| FBC-MSO | 6.6/√3 | 150 | * | 145 | 430 | 655 | 135 | Internal fuse |
| FBC-MSO | 6.6/√3 | 200 | * | 145 | 520 | 745 | 135 | Internal fuse |
| FBC-MSO | 6.6/√3 | 250 | * | 145 | 620 | 845 | 135 | Internal fuse |
| FBC-MSO | 6.6/√3 | 300 | * | 185 | 580 | 805 | 135 | Internal fuse |
| FBC-MSO | 7.2/√3 | 100 | * | 145 | 330 | 555 | 135 | Internal fuse |
| FBC-MSO | 7.2/√3 | 150 | * | 145 | 430 | 655 | 135 | Internal fuse |
| FBC-MSO | 7.2/√3 | 200 | * | 145 | 530 | 755 | 135 | Internal fuse |
| FBC-MSO | 7.2/√3 | 250 | * | 145 | 630 | 845 | 135 | Internal fuse |
| FBC-MSO | 7.2/√3 | 300 | * | 185 | 590 | 815 | 135 | Internal fuse |
| FBC-MSO | 11/√3 | 250 | * | 145 | 620 | 925 | 135 | Internal fuse |
| FBC-MSO | 11/√3 | 300 | * | 185 | 580 | 885 | 135 | Internal fuse |
| FBC-MSO | 11/√3 | 350 | * | 185 | 650 | 955 | 135 | Internal fuse |
| FBC-MSO | 11/√3 | 400 | * | 185 | 730 | 1035 | 135 | Internal fuse |
| FBC-MSO | 12/√3 | 250 | * | 145 | 620 | 925 | 135 | Internal fuse |
| FBC-MSO | 12/√3 | 300 | * | 185 | 570 | 875 | 135 | Internal fuse |
| FBC-MSO | 12/√3 | 350 | * | 185 | 650 | 955 | 135 | Internal fuse |
| FBC-MSO | 12/√3 | 400 | * | 185 | 730 | 1035 | 135 | Internal fuse |
| FBC-MSO | 11 | 400 | * | 185 | 740 | 1045 | 135 | Internal fuse |
| FBC-MSO | 11/√3 | 200 | * | 145 | 530 | 835 | 135 | Internal fuse |
| FBC-MSO | 12/√3 | 200 | * | 145 | 520 | 825 | 135 | Internal fuse |
| FBC-MSO | 10.5/√3 | 334 | * | 185 | 620 | 925 | 135 | Internal fuse |
| FBC-MSO | 11/2 | 334 | * | 185 | 640 | 945 | 135 | Internal fuse |
| FBC-MSO | 12/2 | 334 | * | 185 | 640 | 945 | 135 | Internal fuse |
| FBC-MSO | 11/√3 | 334 | * | 185 | 640 | 945 | 135 | Internal fuse |
| FBC-MSO | 12/√3 | 334 | * | 185 | 620 | 925 | 135 | Internal fuse |
| FBC-MSO | 11 | 334 | * | 185 | 760 | 1065 | 275 | Internal fuse |
| FBC-MSO | 12 | 334 | * | 185 | 760 | 1065 | 275 | Internal fuse |
| FBC-MSO | 11/√3 | 417 | * | 185 | 770 | 1075 | 275 | Internal fuse |
| FBC-MSO | 12/√3 | 417 | * | 185 | 770 | 1075 | 275 | Internal fuse |
| FBC-MSO | 11/2 | 417 | * | 185 | 760 | 1065 | 275 | Internal fuse |
| FBC-MSO | 12/2 | 417 | * | 185 | 760 | 1065 | 275 | Internal fuse |
| FBC-MSO | 11/2 | 500 | * | 210 | 820 | 1125 | 300 | Internal fuse |
| FBC-MSO | 12/2 | 500 | * | 210 | 820 | 1125 | 300 | Internal fuse |
| FBC-MSO | 21/2 | 500 | * | 210 | 840 | 1145 | 300 | Internal fuse |
| FBC-MSO | 23/2 | 500 | * | 210 | 820 | 1125 | 300 | Internal fuse |
| FBC-MSO | 11/√3 | 500 | * | 210 | 800 | 1105 | 135 | upon request |
| FBC-MSO | 11/√3 | 600 | * | 210 | 920 | 1225 | 135 | upon request |
| FBC-MSO | 12/√3 | 500 | * | 210 | 780 | 1085 | 135 | upon request |
| FBC-MSO | 12/√3 | 600 | * | 210 | 900 | 1205 | 135 | upon request |
| FBC-MSO | 11 | 417 | * | 185 | 800 | 1105 | 135 | upon request |
| FBC-MSO | 11 | 500 | * | 210 | 830 | 1135 | 135 | upon request |
| FBC-MSO | 11 | 556 | * | 210 | 910 | 1215 | 135 | upon request |
| FBC-MSO | 11 | 667 | * | 210 | 1050 | 1355 | 135 | upon request |
| FBC-MSO | 12 | 417 | * | 185 | 850 | 1155 | 135 | upon request |
| FBC-MSO | 12 | 500 | * | 210 | 840 | 1145 | 135 | upon request |
| FBC-MSO | 12 | 556 | * | 210 | 910 | 1215 | 135 | upon request |
| FBC-MSO | 12 | 667 | * | 210 | 1050 | 1355 | 135 | upon request |
| FBC-MSO | 21/2 | 334 | * | 145 | 840 | 1145 | 135 | upon request |
| FBC-MSO | 21/2 | 417 | * | 185 | 830 | 1135 | 135 | upon request |
| FBC-MSO | 23/2 | 334 | * | 145 | 820 | 1125 | 135 | upon request |
| FBC-MSO | 23/2 | 417 | * | 185 | 780 | 1085 | 135 | upon request |
| FBC-MSO | 22/√3 | 334 | * | 145 | 850 | 1155 | 135 | upon request |
| FBC-MSO | 22/√3 | 417 | * | 145 | 1000 | 1305 | 135 | upon request |
| FBC-MSO | 22/√3 | 500 | * | 185 | 930 | 1235 | 135 | upon request |
| FBC-MSO | 24/√3 | 334 | * | 145 | 840 | 1145 | 135 | upon request |
| FBC-MSO | 24/√3 | 417 | * | 145 | 980 | 1285 | 135 | upon request |
| FBC-MSO | 24/√3 | 500 | * | 185 | 910 | 1215 | 135 | upon request |
| FBC-MSO | 12 | 1000 | * | 380 | 1200 | 1505 | 135 | upon request |
Table 2. The external fuse and fuseless HV power capacitor
| Model | Rated voltage KV | Rated output Kvar | Case Dimension (mm) | Total height (mm) | Terminals D (mm) | Remark | ||
|---|---|---|---|---|---|---|---|---|
| L | W | H | ||||||
| FBC-MSO | 6.6/√3 | 34 | * | 145 | 200 | 425 | 135 | external fuse/fuseless |
| FBC-MSO | 6.6/√3 | 50 | * | 145 | 200 | 425 | 135 | external fuse/fuseless |
| FBC-MSO | 6.6/√3 | 67 | * | 145 | 240 | 465 | 135 | external fuse/fuseless |
| FBC-MSO | 6.6/√3 | 100 | * | 145 | 310 | 535 | 135 | external fuse/fuseless |
| FBC-MSO | 6.6/√3 | 134 | * | 145 | 380 | 605 | 135 | external fuse/fuseless |
| FBC-MSO | 7.2/√3 | 34 | * | 145 | 200 | 425 | 135 | external fuse/fuseless |
| FBC-MSO | 7.2/√3 | 50 | * | 145 | 200 | 425 | 135 | external fuse/fuseless |
| FBC-MSO | 7.2/√3 | 67 | * | 145 | 240 | 465 | 135 | external fuse/fuseless |
| FBC-MSO | 7.2/√3 | 100 | * | 145 | 310 | 535 | 135 | external fuse/fuseless |
| FBC-MSO | 7.2/√3 | 134 | * | 145 | 380 | 605 | 135 | external fuse/fuseless |
| FBC-MSO | 11/√3 | 50 | * | 145 | 200 | 505 | 135 | external fuse/fuseless |
| FBC-MSO | 11/√3 | 100 | * | 145 | 310 | 615 | 135 | external fuse/fuseless |
| FBC-MSO | 11/√3 | 150 | * | 145 | 400 | 705 | 135 | external fuse/fuseless |
| FBC-MSO | 11/√3 | 200 | * | 145 | 500 | 805 | 135 | external fuse/fuseless |
| FBC-MSO | 11/√3 | 234 | * | 145 | 580 | 885 | 135 | external fuse/fuseless |
| FBC-MSO | 12/√3 | 50 | * | 145 | 200 | 505 | 135 | external fuse/fuseless |
| FBC-MSO | 12/√3 | 100 | * | 145 | 300 | 605 | 135 | external fuse/fuseless |
| FBC-MSO | 12/√3 | 150 | * | 145 | 400 | 705 | 135 | external fuse/fuseless |
| FBC-MSO | 12/√3 | 200 | * | 145 | 500 | 805 | 135 | external fuse/fuseless |
| FBC-MSO | 12/√3 | 234 | * | 145 | 580 | 885 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 50 | * | 145 | 200 | 505 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 100 | * | 145 | 310 | 615 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 150 | * | 145 | 420 | 725 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 200 | * | 145 | 520 | 825 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 250 | * | 145 | 620 | 925 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 300 | * | 185 | 580 | 885 | 135 | external fuse/fuseless |
| FBC-MSO | 11 | 400 | * | 185 | 730 | 1035 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 50 | * | 145 | 200 | 505 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 100 | * | 145 | 310 | 615 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 150 | * | 145 | 420 | 725 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 200 | * | 145 | 520 | 825 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 250 | * | 145 | 620 | 925 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 300 | * | 145 | 580 | 885 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 350 | * | 185 | 660 | 965 | 135 | external fuse/fuseless |
| FBC-MSO | 12 | 400 | * | 185 | 730 | 1035 | 135 | external fuse/fuseless |
Frequently Asked Questions
What system voltages are supported by these HV power capacitors?
Our high-voltage power capacitors are designed for systems with operating voltages above 6KV, and they support a maximum rated capacitor voltage of up to 24KV.
What is the capacity range of your high-voltage capacitors?
We offer a wide capacity range spanning from 50Kvar up to 1000Kvar to meet various industrial power compensation requirements.
What types of fuse configurations are available?
We provide three different configurations based on your application needs: internal fuse, external fuse, and fuseless options.
How are the phases connected internally?
These capacitors feature a 3-phase, internal Y (wye) connection, equipped with dedicated discharge resistors for each phase to ensure safety.
Can I request custom capacitor specifications?
Yes. While standard models are listed in our specification tables, customized dimensions, rated voltages, and outputs are available upon request.