0102030405
Power Factor Correction Shunt Capacitors by China Suppliers | High-Quality Factory Solutions for Reactive Power Compensation
Flair Shunt capacitor design features
Dielectric: Metalized film
Filling Material: heat convertible resin
Safety protection device: each elements are mouting safety protection device to protect capacitor from explosion or short-circuit failures. So as to guarantee the failure elements being separated with circuits.
Buit-in discharge resistor: available
Package: stainless steel shell, hermetically sealed
Frequency: 50Hz
Shell: 1mm galvanized stainless steel shell with good heat dissipation effect
Spacing: Sufficient space between elements, benficial for heat dissipation and lower internal temperature;
Fuse: Internal fuse available
Connection: Internal copper busbar connection (low current density, low contact resistance, low loss)
Discharge Resistor: Fixed connection discharge resistor (Decrease the voltage below 75V after power cut-off within 3 minutes, upon request)
Environment temperature: -20C~+50 C
Altitude: below 2000m
Specification Table
| Model | Capacity | Current | Capacitance | Weight | Dimension (mm) | ||
|---|---|---|---|---|---|---|---|
| Kvar | A | uf | kg | Length | Width | Height | |
| 3-phase 400VAC 50Hz Indoor | |||||||
| FACS-BC3 | 25 | 20.8×3 | 166×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 30 | 25.0×3 | 199×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 40 | 33.3×3 | 265×3 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3 | 50 | 41.7×3 | 332×3 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3 | 60 | 50.0×3 | 398×3 | 9.0 | 200~240 | 112 | 435 |
| 3-phase 460VAC 50Hz Indoor | |||||||
| FACS-BC3 | 20 | 14.5×3 | 100×3 | 4.2 | 200~240 | 112 | 178 |
| FACS-BC3 | 25 | 18.1×3 | 125×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 30 | 21.7×3 | 150×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 40 | 29.0×3 | 201×3 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3 | 50 | 36.2×3 | 251×3 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3 | 60 | 43.5×3 | 301×3 | 9.0 | 200~240 | 112 | 435 |
| The capacitor internal is not connected; Generally used for capacitor triangle connection angle in the fling-cut switch. | |||||||
| Model | Capacity | Current | Capacitance | Weight | Dimension | ||
|---|---|---|---|---|---|---|---|
| Kvar | A | uf | kg | Length | Width | Height | |
| 3 phase 400VAC 50Hz | |||||||
| FACS-BC3Y | 6 | 8.7 | 119 | 3.6 | 200~240 | 112 | 114 |
| FACS-BC3Y | 12 | 17.3 | 239 | 4.3 | 200~240 | 112 | 178 |
| FACS-BC3Y | 18 | 26.0 | 358 | 5.1 | 200~240 | 112 | 242 |
| FACS-BC3Y | 24 | 34.6 | 477 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3Y | 30 | 43.3 | 597 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3Y | 36 | 52.0 | 716 | 9.1 | 200~240 | 112 | 435 |
| 3phase 440VAC 50Hz | |||||||
| FACS-BC3Y | 7 | 9.2 | 115 | 3.6 | 200~240 | 112 | 114 |
| FACS-BC3Y | 14 | 18.4 | 230 | 4.3 | 200~240 | 112 | 178 |
| FACS-BC3Y | 21 | 27.6 | 345 | 5.1 | 200~240 | 112 | 242 |
| FACS-BC3Y | 29 | 38.1 | 477 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3Y | 36 | 47.2 | 592 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3Y | 43 | 56.4 | 707 | 9.1 | 200~240 | 112 | 435 |
| The capacitor internal is wye connection; | |||||||
| Model | Capacity | Current | Capacitance | Weight | Dimension(mm) | ||
|---|---|---|---|---|---|---|---|
| Kvar | A | uf | kg | Length | Width | Height | |
| 3-phase 400VAC 50Hz Indoor, | |||||||
| FACS-BC | 20 | 28.9 | 398 | 4.2 | 200~240 | 112 | 178 |
| FACS-BC | 25 | 36.1 | 497 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 30 | 43.3 | 597 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 40 | 57.7 | 796 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC | 50 | 72.2 | 995 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC | 60 | 86.6 | 1194 | 9.0 | 200~240 | 112 | 435 |
| 3-phase 460VAC 50Hz indoor | |||||||
| FACS-BC | 20 | 25.1 | 301 | 4.2 | 200~240 | 112 | 178 |
| FACS-BC | 25 | 31.4 | 376 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 30 | 37.7 | 451 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 40 | 50.2 | 602 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC | 50 | 62.8 | 752 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC | 60 | 73.3 | 903 | 9.0 | 200~240 | 112 | 435 |
| The harmonic filtering capacitor is usually connect with reactor in series to filter the frequency harmonic in the powe system; | |||||||
Frequently Asked Questions (FAQ)
What type of dielectric and filling materials are used in Flair Shunt capacitors?
Flair Shunt capacitors are designed with a metalized film dielectric and filled with a heat convertible resin to ensure stable performance and durability.
How does the safety protection device work?
Each element is mounted with an individual safety protection device. This prevents explosion or short-circuit failures by guaranteeing that any failed element is immediately separated from the operational circuits.
What are the environmental and installation limits for these capacitors?
These capacitors are rated for an environment temperature range of -20°C to +50°C and are suitable for installation at altitudes below 2000 meters.
Does the capacitor feature a discharge resistor?
Yes, a built-in discharge resistor is available. Upon request, a fixed connection discharge resistor can decrease the voltage to below 75V within 3 minutes after a power cut-off.
What are the differences between the FACS-BC3, FACS-BC3Y, and FACS-BC models?
FACS-BC3 features internal elements that are not connected (typically used for triangle/delta connection in fling-cut switches). FACS-BC3Y utilizes a wye (star) connection. FACS-BC is designed as a harmonic filtering capacitor, usually connected in series with a reactor to filter system harmonics.