Power Factor Correction Shunt Capacitors from China Suppliers - Quality Factory Solutions for Reactive Power Compensation
Flair Shunt capacitor design features
Dielectric: Metalized film
Filling Material: Heat convertible resin
Safety protection device: Each elements are mounting safety protection device to protect capacitor from explosion or short-circuit failures. So as to guarantee the failure elements being separated with circuits.
Built-in discharge resistor: Available for added safety.
Package: Stainless steel shell, hermetically sealed
Frequency: 50Hz
Shell: 1mm galvanized stainless steel shell with good heat dissipation effect
Spacing: Sufficient space between elements, beneficial for heat dissipation and lower internal temperature
Internal fuse: Available for protection
Busbar connection: Internal copper busbar connection (low current density, low contact resistance, low loss)
Fixed connection discharge resistor: Decrease the voltage below 75V after power cut-off within 3 minutes, upon request
Environment temperature: -20°C ~ +50°C
Altitude: Below 2000m
Specification Table
| Model | Capacity | Current | Capacitance | Weight | Dimension (mm) | ||
| Kvar | A | uf | kg | Length | Width | Height | |
| 3-phase 400VAC 50Hz Indoor | |||||||
| FACS-BC3 | 25 | 20.8×3 | 166×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 30 | 25.0×3 | 199×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 40 | 33.3×3 | 265×3 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3 | 50 | 41.7×3 | 332×3 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3 | 60 | 50.0×3 | 398×3 | 9.0 | 200~240 | 112 | 435 |
| 3-phase 460VAC 50Hz Indoor | |||||||
| FACS-BC3 | 20 | 14.5×3 | 100×3 | 4.2 | 200~240 | 112 | 178 |
| FACS-BC3 | 25 | 18.1×3 | 125×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 30 | 21.7×3 | 150×3 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC3 | 40 | 29.0×3 | 201×3 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3 | 50 | 36.2×3 | 251×3 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3 | 60 | 43.5×3 | 301×3 | 9.0 | 200~240 | 112 | 435 |
| The capacitor internal is not connected; Generally used for capacitor triangle connection angle in the fling-cut switch. | |||||||
|
|||||||
| Model | Capacity | Current | Capacitance | Weight | Dimension | ||
| Kvar | A | uf | kg | Length | Width | Height | |
| 3 phase 400VAC 50Hz | |||||||
| FACS-BC3Y | 6 | 8.7 | 119 | 3.6 | 200~240 | 112 | 114 |
| FACS-BC3Y | 12 | 17.3 | 239 | 4.3 | 200~240 | 112 | 178 |
| FACS-BC3Y | 18 | 26.0 | 358 | 5.1 | 200~240 | 112 | 242 |
| FACS-BC3Y | 24 | 34.6 | 477 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3Y | 30 | 43.3 | 597 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3Y | 36 | 52.0 | 716 | 9.1 | 200~240 | 112 | 435 |
| 3phase 440VAC 50Hz | |||||||
| FACS-BC3Y | 7 | 9.2 | 115 | 3.6 | 200~240 | 112 | 114 |
| FACS-BC3Y | 14 | 18.4 | 230 | 4.3 | 200~240 | 112 | 178 |
| FACS-BC3Y | 21 | 27.6 | 345 | 5.1 | 200~240 | 112 | 242 |
| FACS-BC3Y | 29 | 38.1 | 477 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC3Y | 36 | 47.2 | 592 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC3Y | 43 | 56.4 | 707 | 9.1 | 200~240 | 112 | 435 |
| The capacitor internal is wye connection; | |||||||
|
|||||||
| Model | Capacity | Current | Capacitance | Weight | Dimension(mm) | ||
| Kvar | A | uf | kg | Length | Width | Height | |
| 3-phase 400VAC 50Hz Indoor, | |||||||
| FACS-BC | 20 | 28.9 | 398 | 4.2 | 200~240 | 112 | 178 |
| FACS-BC | 25 | 36.1 | 497 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 30 | 43.3 | 597 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 40 | 57.7 | 796 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC | 50 | 72.2 | 995 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC | 60 | 86.6 | 1194 | 9.0 | 200~240 | 112 | 435 |
| 3-phase 460VAC 50Hz indoor | |||||||
| FACS-BC | 20 | 25.1 | 301 | 4.2 | 200~240 | 112 | 178 |
| FACS-BC | 25 | 31.4 | 376 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 30 | 37.7 | 451 | 5.0 | 200~240 | 112 | 242 |
| FACS-BC | 40 | 50.2 | 602 | 6.5 | 200~240 | 112 | 306 |
| FACS-BC | 50 | 62.8 | 752 | 7.8 | 200~240 | 112 | 370 |
| FACS-BC | 60 | 73.3 | 903 | 9.0 | 200~240 | 112 | 435 |
| The harmonic filtering capacitor is usually connect with reactor in series to filter the frequency harmonic in the powe system; | |||||||
|
|||||||
Frequently Asked Questions (FAQ)
What are the dielectric and filling materials used in Flair Shunt capacitors?
The dielectric material is metalized film, and the filling material is heat convertible resin.
How does the safety protection device protect the capacitor?
Each element is mounted with a safety protection device to protect the capacitor from explosion or short-circuit failures, ensuring that failed elements are separated from the circuits.
What are the specifications of the capacitor's outer shell?
The capacitor features a 1mm galvanized stainless steel shell that is hermetically sealed and provides excellent heat dissipation.
What are the environmental limits for operating these capacitors?
The capacitor is designed for environmental temperatures ranging from -20°C to +50°C and altitudes below 2000 meters.
How long does it take for the discharge resistor to reduce voltage?
The fixed connection discharge resistor can decrease the voltage below 75V within 3 minutes after a power cut-off, upon request.
What is the difference between the FACS-BC3, FACS-BC3Y, and FACS-BC models?
FACS-BC3 capacitors are not internally connected and are used for triangle connections in fling-cut switches. FACS-BC3Y capacitors feature an internal wye connection. FACS-BC harmonic filtering capacitors are designed to connect with reactors in series to filter frequency harmonics.